Table C-6: Disk Channel Error Codes and Descriptions

Error

Code

IFS_66

04

05

Description

Data overrun or underrun occurred while getting sense data

20

23

22

21

31

30

24

32

40

Request for sense data failed

Selection timeout (displayed as “Sel Timout”)

Controller detected an unrecoverable protocol error on the part of the target

Unexpected bus-free condition (displayed as Unex Bsfree”)

Parity error on data received from a target (displayed as “Parity Err”

Target reported busy status (displayed as “Device Busy”)

Target reported queue full status (displayed as “Queue Full”)

Target has been reserved by another initiator

Controller decided to abort I/O request for reasons other than bus or target reset

Data overrun or underrun has been detected (displayed as “Data OvUnRun”

41

45

44

43

42

46

4B

50

Controller aborted an I/O request to this target because it timed out

(displayed as “I/O Timeout”)
I/O request was aborted because of a channel reset

I/O request was aborted because controller’s decision to reset the channel

I/O request was aborted because of third-party channel reset

I/O request was aborted because of target reset requested by the controller

Target did not respond properly to abort sequence
I/O aborted due to operating mode change (ie. LVD to S.E. or S.E. to LVD)

(displayed as “Abort MdChg”)
Disk channel hardware failure (displayed as “Dsk Chn Fail”) - possibly caused by

bad termination or cabling.