Integrated function controller, Svsound – SVS PB12-Plus User Manual

Page 18

Advertising
background image

© 2011 Specialty Technologies, LLC

Call SVSound

877.626.5623

www.svsound.com

SVSound

STA-800D/1000D Equipped Subs

Refer to the section later in this guide titled “Advanced Features: Parametric Equalizer (PEQ)” for more details

on how to actually use the PEQ features of the STA-800D/STA-1000D.

From the IFC WELCOME screen, single-click the IFC knob and rotate the IFC knob seven clicks clockwise until

the display reads “MENU/P-EQ”. Single-click the IFC knob to select the PEQ1 Function or rotate the IFC knob

clockwise or counter-clockwise and single-click to select PEQ2 Function.

From the PEQ1/PEQ2 Function menu, single-click to select the desired PEQ band Frequency menu (to skip to

the Level Menu or Q Menu, turn the IFC knob the appropriate number of turns). Single-click to change the PEQ

band center frequency. When selected, the display will be blinking and the value will change as the IFC knob is

turned. Available center frequencies include 31, 35, 40, 46, 50, 56, 63, 70, 80, 90, 100, 112, or 125Hz. To save

the displayed frequency, single-click the IFC knob. To proceed to either the Level Menu or Q Menu rotate the

IFC the required number of turns.

To adjust the Level, single-click the IFC knob when the display reads PEQ1 or PEQ2 LEVEL. The screen will begin to

flash and you can change the Level of the PEQ filter by turning the IFC knob clockwise or counter-clockwise.(NOTE:

To disable the PEQ1 or PEQ2 filter, set the level to 0 dB.) The Level can be adjusted from +3 to -12 dB in 1 dB incre-

ments. To save the displayed level, single-click the IFC knob. To proceed to the Q Menu, rotate the IFC knob.

Note: Some dips are actually nulls and boosting a null will not produce an increase in level when a positive

value is applied. To limit potential damage to the subwoofer, the amount of boost has been limited to +3 dB.

To adjust Q (width) for the PEQ1 or PEQ 2 filter, single-click the IFC knob when the display reads PEQ1 or PEQ2

Q. The screen will begin to flash and you can change the Q of the PEQ filter by turning the IFC knob clockwise

or counter-clockwise. Q values can be set to 2.0, 2.4, 2.9, 3.6, 4.8, 5.7, 7.2, 9.6, or 14.4. To save the displayed

Q value, single-click the IFC knob.

At this point, a single-click will return to either the PEQ1 or PEQ2 Function Menu unless the Level is set to 0 dB.

If that is the case, a single-click will return to the PEQ Menu where the PEQ1 or PEQ2 function can be selected.

To return to the top-level menu, double-click the IFC knob.

Integrated Function Controller

18

Advertising
This manual is related to the following products: