Wiring schematics - residential, Nsw installation manual, Legend – WaterFurnace Envision Hydronic (NSW) User Manual

Page 18

Advertising
background image

18

NSW INSTALLATION MANUAL

Wiring Schematics - Residential

NSW Heating Only - 208-230/60/1

Transformer

NOTE 1

Red
208V

Black

Com

Compressor

Unit

Power Supply

CC

T1

L1

T2

Tan

Brown

Blue

G

C

R

S

Black

Red

Blue

Factory low voltage wiring

Legend

Switch - High pressure

Switch - Low pressure

Relay coil

Field wire lug

Ground

Relay Contacts -

N.O., N.C.

Polarized connector

Notes:

Factory line voltage wiring
Field low voltage wiring
Field line voltage wiring
Optional block
Quick connect terminal

Screw terminal - field connection

CC -

-

HP -

LP -

LPR -

Compressor contactor

High pressure switch

Low pressure switch

Load Pump Relay

L1

1

3

2

P

Capacitor

24V

Microprocessor Control

TEST

PIN

HP

HP

CC

CG

HI

LO

C

LP

LP

R

HP

HP

CC

CG

HI

LO

C

LP

LP

R

CC

HP

LP

Black/

White

Blk/Wht

Violet
Black
Black

White/Blue
White/Blue

Red

LPR

T

T

RT

ELT

Orange

X

1

E

LT

E

LT

R

T

R

T

X2

X1

X

1

E

LT

E

LT

R

T

R

T

X

2

X

1

RV

Reversing Valve output

ELT - Entering Load Side Water Temperature

Green/Yellow

T

Thermistor

P1

P2

P3

X

3

X

3

X3

X

3

LPR

Interface Panel

Black

Black

Yellow

Yellow

Violet

Violet

Orange

Orange

Gray

Gray

1
2

3
4
5
6
7
8

TB

1

1

G

Load

Pump

External

X2

X2

PS1

RV RVG

RT - Refrigerant Liquid line Temperature

SI

SI - Slave Input relay

R C Y1 O X1

G

External

SI

RC - Reversing Valve Coil

Fuse

Cap

9

10

11

12

1. Taped and wire tied off

Not Used

Not Used
Not Used
Not Used
Not Used

Green/Yellow

Yellow

24 V

B

C

D

L2

L2

L1

L1

T1

T1

T2

T2

LFB

SFB

LFB -

SFB -

Load Pump Fuse Block

Source Pump Fuse Block

NOTE 2

2. 3 AG 10 Amp fuse

Blue/Wht

Brown/Wht

Brown/Blk

Red

Black

Orange

Black/Gry

Violet

Black/Wht

L2

208-230/60/1

Source

Pump

MODE

3. For cycle load pump with a geo storage

tank. Remove the orange wire from the LPR
relay coil and install a jumper between the
LPR relay coil and the comp contactor coil
as shown in the schematic above.

Note 3

Blue

230V

04/02/09

Advertising