PLL Features

Table 2-4: MAX 10 PLL Features

Feature

Support

C

output counters

5

M

,

N

,

C

counter sizes

1 to 512

(2)

Dedicated clock outputs

1 single-ended or 1 differential

Dedicated clock input pins

4 single-ended or 2 differential

Spread-spectrum input clock tracking

Yes

(3)

PLL cascading

Through GCLK

Source synchronous compensation

Yes

No compensation mode

Yes

Normal compensation

Yes

Zero-delay buffer compensation

Yes

Phase shift resolution

Down to 96 ps increments

(4)

Programmable duty cycle

Yes

Output counter cascading

Yes

Input clock switchover

Yes

User mode reconfiguration

Yes

Loss of lock detection

Yes

4:1 multiplexer

CLK

input selection

Yes

PLL Locations

The following figures show the physical locations of the PLLs. Every index represents one PLL in the

device. The physical locations of the PLLs correspond to the coordinates in the Quartus II Chip Planner.

(2)

C

counters range from 1 through 512 if the output clock uses a 50% duty cycle. For any output clocks using a

non-50% duty cycle, the post-scale counters range from 1 through 256.

(3)

Only applicable if the input clock jitter is in the input jitter tolerance specifications.

(4)

The smallest phase shift is determined by the VCO period divided by eight. For degree increments, the

MAX 10 device family can shift all output frequencies in increments of at least 45°. Smaller degree

increments are possible depending on the frequency and divide parameters.