The OVERTEMPn and TSENSE_ALERTn signals are driven by the MAX1619 temperature
sense device based on a programmable threshold temperature. The OVERTEMPn signal
is driven to the MAX II System Controller. An over-temperature warning LED (D7)
indicates the temperature fault condition.

Table 2–44

lists the temperature sense interface pin assignments, signal names, and

functions.

Table 2–45

lists the temperature sense component reference and manufacturing

information.

Statement of China-RoHS Compliance

Table 2–46

lists hazardous substances included with the kit.

Table 2–44. Temperature Sense Pin Assignments, Schematic Signal Names, and Functions

Board

Reference

(U12)

Schematic Signal

Name

I/O

Standard

MAX II CPLD

System Controller

Pin Number

Stratix V GX

Device

Pin Number

Description

14

SMBCLK_TEMP

3.3-V

D3

B8

SMB clock

12

SMBDATA_TEMP

C2

A8

SMB data

11

ALERTn

D2

E8

Programmable alert

9

OVERTEMPn

E4

E7

Fan enable

3

TEMPDIODE_P

V11

Current source and remote
diode input

4

TEMPDIODE_N

U11

Remote diode input

Table 2–45. Temperature Sense Component Reference and Manufacturing Information

Board Reference

Description

Manufacturer

Manufacturing

Part Number

Manufacturer

Website

U12

Temperature sense, remote and
local, programmable alert.

Maxim

MAX1619MEE+T

www.maxim-ic.com

Table 2–46. Table of Hazardous Substances’ Name and Concentration

Notes

(1)

,

(2)

Part Name

Lead

(Pb)

Cadmium

(Cd)

Hexavalent

Chromium

(Cr6+)

Mercury

(Hg)

Polybrominated
biphenyls (PBB)

Polybrominated

diphenyl Ethers

(PBDE)

Stratix V GX transceiver signal
integrity development board

X*

0

0

0

0

0

14 V power supply

0

0

0

0

0

0

Type A-B USB cable

0

0

0

0

0

0

User guide

0

0

0

0

0

0

Notes to

Table 2–46

:

(1) 0 indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the relevant threshold of the

SJ/T11363-2006 standard.

(2) X* indicates that the concentration of the hazardous substance of at least one of all homogeneous materials in the parts is above the relevant

threshold of the SJ/T11363-2006 standard, but it is exempted by EU RoHS.