Using the oscillator, Hi lo ➜ bypass int ➜ ➜ ext – Applied Motion PDO2035 User Manual

Page 10

Advertising
background image

Using the Oscillator

The PDO2035 is equipped with an internal pulse
generator that you can use to control the motor. To
select the oscillator mode of operation (run/stop mode)
move switch 2 away from the

BYPASS label, as shown

at the right.

The oscillator is activated by driving the

STEP input low. The frequency of step

pulses will increase linearly, accelerating the motor until it reaches a preset slew
speed. The motor will remain at this speed until the

STEP input is driven high. The

step pulse frequency then decreases linearly, decelerating the motor and load to
rest. The PDO2035 lets you choose from two oscillator speed ranges: 10 - 1200
steps/second (LO) and 100 - 12000 steps/sec (HI). Set the speed range with the
"LO/HI" switch.

3362

20,000

steps/sec

2

10,000

steps/sec

2

5000 steps/sec

2

2500 steps/sec

2

1200 steps/sec

2

600

steps/sec

2

300

steps/sec

2

150

steps/sec

2

(no ramp)

To adjust the speed, locate the trimpot labeled

SPEED . By turning the brass screw

you can raise or lower the speed within the range you have selected. Turning the
screw clockwise makes the motor run faster.

The acceleration and deceleration rates can also be adjusted using the trimpots
labeled

ACCEL and DECEL. The range of accel and decel rates is illustrated below.

Turning the screw clockwise makes the motor accelerate or decelerate faster.

123

HI

LO

BYPASS

INT

EXT

123

HI

LO

BYPASS

INT

EXT

123

HI

LO

BYPASS

INT

EXT

10 - 1200 steps/sec

100 - 12000 steps/sec

A+

A–

B+

B–

8

lead

motor

8 Leads Series Connected

Eight lead motors can also be connected in two ways: series and parallel. As
with six lead motors, series operation gives you more torque at low speeds and less
torque at high speeds. In series operation, the motor should be operated at 30%
less than the rated current to prevent over heating. The wiring diagrams for eight
lead motors are shown below.

8 Leads Parallel Connected

A+

A–

B+

B–

8

lead

motor

Orange

Org/Wht

Blk/Wht

Black

Red

Red/

Wht

Yel/
Wht

Yellow

Orange

Org/

Wht

Blk/Wht

Black

Red

Red/Wht

Yel/
Wht

Yel
low

Step

A+

A-

B+

B-

0

+

+

1

+

+

2

+

+

3

+

+

4

+

+

DIR=1

cw

DIR=0

ccw

Step 3 is the Power Up State

Step Table

(full stepping)

-7-

-10-

200,000

steps/sec

2

100,000

steps/sec

2

50,000 steps/sec

2

25,000 steps/sec

2

12000 steps/sec

2

6000

steps/sec

2

3000

steps/sec

2

1500

steps/sec

2

(no ramp)

LO range accel/decel settings

Shown at 2500 steps/sec

2

HI range accel/decel settings

Shown at 25,000 steps/sec

2

3362

(speed range)

(internal oscillator)

(potentiometer)

Advertising