Atlona AT SDI82M User Manual

Page 6

Advertising
background image

4

RS232 Commands

RS-232 transmission format:
Baud rate : 115200 bps

Data bit : 8 bits

Parity : None
ASCII Command Mode

Command

ACK

Description

VR

V2.01a

Read Version V2.01a [Firmware Version]

I1~8

Input Select ( AT-SDI81 & AT-SDI82M [1~8]; AT-SDI51 &

AT-SDI52M [1~5])

ST

OUTPUT1

Read Selected Source OUTPUT1

Input one selected ( AT-SDI81 & AT-SDI82M [1~8]; AT-SDI51 &

AT-SDI52M [1~5])

Serial String Mode

Format:

First byte

Transmission data amount [from first byte to last byte]

0x53

Check code

0x57

Check code

0x30

Check code

0x88

Check code

0xff

*Machine Number

0x01

Command ID

....

Command Parameters

Last byte…

Check sum [Add from first byte to command Parameters]

Note : If send Machine Number as 0xFF, All switch can receive the command,otherwise the machine number must

be the same as the Switcher

(a)Set command :

Command code

Response

Description

DATA

*CHECK SUM

ACK

SET

0x09 0x53 0x57 0x30 0x08

0xff 0x02 0x01~0x08

0xed~0xf4

0xaa

0x03

0x01

0x04

Select input Source

0x09: Command Length

0x53 0x57 0x30 0x08: Check Code

0xff :Machine number

0x02: Command ID

0x01~0x08: Input Source

( AT-SDI81 & AT-SDI82M [0x01~0x08];

AT-SDI51 & AT-SDI52M [0x01~0x05])

0xed~0xf4: Check sum

Ack

0xaa: Header

0x03: Command length

0x01: Selected source

0x04: Check Sum

Advertising
This manual is related to the following products: