- 36 -

SLP-TX400x/TX403x

6-2 Cleaning Sensors, Roller or/and Paper Path

1) Open the paper cover and ribbon assembly, and remove the paper and ribbon.

2) Remove any dust or foreign substance using dry cloth or cotton swab.

3) Soak the cloth or cotton swab in alcohol for medical use and use it to remove adhesive

foreign substances or other pollution materials.

4) After cleaning the parts, do not use the printer until the alcohol evaporates completely

(1~2 min) and the printer has completely dried


Clean the parts when there is a degradation of performance in printing quality or paper

detection.

Paper Guide+Gap Sensor

Black-Mark & Notch

Sensor

Paper Holder

Peel-off Sensor

(Option)

Platen Roller

Peel-off Roller

Ridges

Paper Roller

Head Cover

Ridges