Specifications – Casella CEL Multimet User Manual

Page 15

Advertising
background image

5.

SPECIFICATIONS

5.1

Anemometer Wind Speed Sensor

Transducer type:

Optical interrupter

Maximum wind speed:

75 m/s

Starting velocity:

Typically 0.3 m/s

Distance constant:

3.5 m/s

Time constant:

Typically <0.5 s

Output calibration:

12.75 Hz/m/s

Resolution:

7.84 cm

Output signal:

0 - 5 V pulses

Pulses/revolution:

20

Non-linearity:

<±0.6%

Accuracy:

±0.3 m/s below 3 m/s

±1% over 3 m/s

Supply voltage:

6 to 28 V DC

Power consumption:

3 mA

Stabilisation time:

<1 s from power up

Operating temperature:

-20 to +70

o

C

Heater option:

24 V DC / AC, 82 Ω, 7 W

Connecting cable:

4.5 m without conduit

3.25 m with conduit

Conduit:

2.55 m

5.2

Weathervane Wind Direction Sensor

Transducer type:

GMR solid state system with

microcontroller

Maximum wind speed:

75 m/s

Resolution:

1

o

Accuracy:

<±2

o

Aligning threshold:

<0.8 m/s for a 10

o

offset

Damping ratio:

0.25

Distance constant:

Typically 3.0 m

Undamped natural wavelength:

2.2 m

Repeatability:

0.5% FSD

Electrical angle:

0 to 359

o

no deadband at North

Nominal output signal:

0 to 1.8 V DC for 0 to 359

o

representing a 1 s rolling average updated

5 times per second

NMEA serial output:

When anemometer is connected, 0 to 5 V

level data containing both direction and

speed information updated 4 times per

second

Supply voltage:

6 to 28 V DC

Power consumption:

3 mA

Stabilisation time:

<1 s from power up

Operating temperature:

-20 to +70

o

C

Specifications

Page 15 of 16

MULTIMET Wind Speed and Direction System
& OnlinePro Software - Users Handbook

Advertising