Lsm fse/pse efa – Future Automation LSM-FSE User Manual

Page 11

Advertising
background image

In

st

all

at

io

n

: S

ta

ge

6

Page 10 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

LSM FSE/PSE EFA -

Lift System with FSE or PSE Mount & Electric Flap Actuator

Attaching EFA (Electric Flap Actuator)

Lower the mechanism by pressing IN (1) then STOP (2) after 100mm [4”] approximately,
then attach the EFA push rod to the flap as shown in detail 3. Loosen the bolts on the push
rod and slide the length to suit the cabinet height, make sure the flap and push rod stands up
vertically as shown in detail 4. Finally (5) fix the EFA drive unit to the base of the cabinet and
tighten the push rod bolts back up.

1

2

4

5

3



40mm
[1.6”]

Make sure that when the mechanism
runs down to the IN position the
beam or cable management chain
doesnt collide with the EFA drive box

Advertising
This manual is related to the following products: