PROTOCOL

ACTION

fa_in Carriage Return (Enter )

Device IN

fa_out Carriage Return (Enter )

Device OUT (90 Degrees)

fa_preset A-F Carriage Return (Enter )

Device to PRESET or A-F memory positions

fa_stop Carriage Return (Enter )

STOPS the device at any position

fa_home Carriage Return (Enter )

Lift UP facing forward (Default Position)

In

st

al

la

ti

o

n

:

R

S

23

2

C

on

tr

ol

Page 17 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

LSM FSE/PSE EFA -

Lift System with FSE or PSE Mount & Electric Flap Actuator

Connection Locations

Mains Voltage Input

IR LED

IR Input Jack

RS232

Contact Closure

Emergency Stop Connector























SLQV

RS232
- Use an RJ25 connector
in the socket marked
RS232 on the control box
to operate using RS232

Details
Baud rate: 9600
Stop bit:

1

Parity:

None

Databits:

8

Pin 1: RX

Pin 6 : TX

Pin 3 & 4: GROUND

Pin 2: TX

Pin 3: RX

Pin 5: GROUND

IMPORTANT
Ensure protocol is entered exactly as written, including Carriage Return (Enter / ASCII 13).

RJ25

9 PIN D

PIN 1: RX

TO

PIN 2: TX

PIN 6: TX

TO

PIN 3: RX

PIN 3: GROUND

TO

PIN 5: GROUND

PIN 4: GROUND

TO

PIN 5: GROUND