Lsm fse/pse efa – Future Automation LSM-FSE User Manual

Page 14

Advertising
background image

In

st

al

la

ti

o

n

:

S

ta

ge

9

Page 13 of 20 // email [email protected] tel: +44 (0) 1438 833577 fax: +44 (0) 1438 833565

LSM FSE/PSE EFA -

Lift System with FSE or PSE Mount & Electric Flap Actuator

You can adjust the IN and OUT position of the lifting beam. Detail 1 shows how
to adjust the OUT position and detail 2 shows how to adjust the IN position.
The IR sensor can be located anywhere outside of the cabinet.

Lift Switch Adjustments

1

2

1 - The top switch can’t
be adjusted when the
mechanism is in the OUT
position, because the
switch is active. Lower
the mechanism and press
STOP about 100mm [4”]
and then adjust the OUT
switch plate.

2 - Height of the lower post
determines the IN position

Advertising