3. INSTALLATION

Operation manual b46, chapter 3 -installation- page 3-3




The digital audio level processor b46 can be remote-controlled
by means of parallel GPI contacts.

use :

remote-controlled changeover of presets

connector:

D-SUB 15pin, female


Pin assignments

Pin

Signal name

Logic

I/O

Functions

1

PRESET1

L

I

recall preset1

2

PRESET2

L

I recall

preset2

3

PRESET3

L

I recall

preset3

4

PRESET4

L

I recall

preset4

5

not used

L

6

BYPASS

L

I bypass

on

7

Transp12

L

I

Input 1/2 transparent

8

Transp34

L

I

Input 3/4 transparent

9

SDI12

L

I

Input 1/2 on SDI

10 SDI34

L

I

Input 3/4 on SDI

11 not

used

12 not

used

13 not

used

14

Common pin

External voltage feed

15

+5V

O

Test power source

Electrical specification:

GPI input

potential free by opto-coupler, low active

OFF:

+3.5…+30V between GPI input

and

pin14

ON:

less then 1.5V

min

50ms


Note: If using an external voltage feed it has to be connected to pin 14!
External Ground is switching the GPI on any of the inputs.
An internal voltage feed is available on pin 15. Ground is available from the
shield of the connector only! By using the internal voltage feed there is no
electrical isolation given anymore.

3.7

REMOTE
CONTROL

3.7.1

GPI REMOTE
CONTROL
(PARALLEL
REMOTE)

min. 50 ms

+1,5V

+3,5...30V

Pin1...13

Ext. voltage
feed+3,5...30V

Pin14

Contact to
ext. Ground

Advertising