Junger Audio b46 - Digital Audio Leveler User Manual

Page 27

Advertising
background image

5. OPERATION


6. menu

PR >ITU BS.1770<

01 off


ITU BS.1770: Weighting of the leveller processing according

to ITU BS.1770. If turned on, the Loudness
Target becomes processing reference (instead
of Operating Level). By default the box is
changing Operating Level less 6dB to
determine Loudness Target (and vice versa).
All measurment definition by ITU (see BS.1770
document for details).

7. menu PROCESSING THR

-60


PROC THRESHOLD:

If the input signal is below this threshold all

remaining GAIN will be taken out.

If the input signal returnes above threshold

previous gain is applied again.

Pls. note this is not a PRESET parameter, but a global setting
for the box!

operation manual b46, chapter 5 -Operation- page 5-5

Advertising