Ethernet Interface Setup

On the CD included with the unit is a program entitled Netburner IPSetup V2.0.

After ensuring that the R-197AV to be set up is powered up, and is connected to your computer,
or to your network, open this program. [If connecting directly from your computer, use a crossover
cable.]

Notice that two netburner devices have been detected.

If yours has not been set up, it will have a default of 192.168.0.2. This should be one of the
choices shown. However, if the IP address has been changed for testing purposes, it may be
another address such as 192.0.0.20..

To change this to the IP address you desired, merely type into the NDK Settings the address IP,
the Gateway and the DNS on the left side to program this address, and then select the default
address. You would then click on Set, and the program will modify your device.

[Another way to modify the address of the server in the unit is to enter the present IP address in a
browser window. Then go to “Setup” in the ensuing screen. If the unit asks for
a password, enter r197set. Then enter the IP desired, the Gateway and the DNS to be used,
click on Save and restart the device by turning the power on and off. ]

Select Close to finish.

If you forget the IP address used for the unit, you must reset the unit to the default address.

Remove power. Using a paper clip, press and hold the reset button down, then re-apply power
to the board. If the button is held down for at least 2 seconds, but less than 8
seconds, Relay1 turns on. Releasing the button during this time will reset the passwords to
default: “r197c” for control, “r197set” for setup, and all settings in the unit will also be reset. If
the button is held down between 8 - 29 seconds, Relay2 will be turned on. Releasing the
button during this time will reset the IP to default: 192.168.0.2, and the passwords and data
will be reset as described before. (If you continue to hold the button down pass 30 seconds,
NOTHING will be reset.)