Monroe Electronics R197AV User Manual

Page 21

Advertising
background image

6. If using the 2nd network interface select the Static (Manually Configure) radio button,
otherwise continue to Step 7.

7. In the Manual Config Options box enter an IP Address that differs by at least one number in
the last octet from the R197AV’s IP address. As an example if the R197AV’s IP address is
192.168.1.2 enter 192.168.1.3. Do not use the same IP numbers.

8. Enter enter the SAME Netmask number set in the R197AV.

9. You can ignore the host name.

10. Click Accept Changes /Restart Network further down the page. The DASDEC will restart
with the new network settings.

11. Log in again

12. Go to Setup > Net Alerts > Net GPIO. Click on the Add NETGPIO Client Interface button
as shown in Figure . A gray box will appear with additional information

13. Turn on the client by
selecting (clicking) in the
box ENABLE Client
Interface
in the gray
area. When activated
additional parameters
can be accessed and
added as shown in

14. Put the IP address of the previously configured R197AV
in the IP Address box. The DASDEC will immediately try to
ping the device. If it cannot “find” the unit a red warning box
(Error: Reference source not found) will be displayed.
Enter the proper IP address to correct and the warning will
disappear.

Reference source not found

21

Advertising