Dca-2/dca-2t & rc-16 specifications, Dca-2/dca-2t digital control attenuator, Rc-16 remote control – Oxmoor DCA-2 User Manual

Page 14

Advertising
background image

DCA-2/DCA-2T & RC-16 SPECIFICATIONS

All specifications subject to change without notice.

DCA-2/DCA-2T DIGITAL CONTROL ATTENUATOR

FREQUENCY RESPONSE

20 Hz to 20 kHz +0, -0.3 dB; -3 dB Points Ref. 1 kHz are
4 Hz and 60 kHz (@ +4 dBm, Max. Gain)

HUM AND NOISE

-80 dB Unweighted (Ref. 0dBm Output, Unity Gain);
100 dB Dynamic Range

DISTORTION

-80 dB (0.01%) THD or IMD* (Ref. +4 dBm, 20 Hz to 20 kHz)

CROSSTALK

-90 dB** (20 Hz to 20 kHz)

INPUTS

Type:

Electronically Balanced (RF Suppressed)

Input:

100 k Ohms

Max. level:

± 20 dBu

CMRR:

50 dB (20 Hz to 20 kHz)

OUTPUTS

Type:

DCA-2: Electronically Unbalanced
DCA-2T: Transformer Balanced

Source:

75 Ohms

Load:

≥ 600 Ohms (stable w/any load)

Max. level:

+18 dB into 600 Ohms, +20 dBu Unterminated

GAIN RANGE

-15 dB to +15 dB (Ref. Unity Gain, RC-16 at Max. Level)

DIGITAL ATTENUATOR

Control Range: 0 to -43.5 dB in 29 Steps, Plus a 90 dB

Full Attentuation (“Kill”) Step

Tracking Accuracy: ± 0.1 dB, Full Range, Interchannel

Preset & Priority Range: 15 steps (3 dB Each) Plus “Kill”

CONTROL LOOP

4 Controls per Channel (Maximum)
64 Channels per Control Chain (Maximum)
600 m (2,000 ft.) Max. Cable to Farthest RC-16 Remote

SAFETY LISTINGS

UL and CE

MAINS POWER

100 to 130V AC or 200 to 260V AC (Switchable),
50 or 60 Hz, 8 Watts Maximum

FUSE TYPE

1/8 Amp SB (115V) or 1/16 Amp SB (230V)

ENVIRONMENTAL

Storage Temperature: -25°C to 70°C (-13°F to 158°F)

Operating Temperature: -10°C to 50°C (14°F to 122°F)

Humidity: < 80% Relative, Non-condensing

MECHANICAL

Overall Dimensions: 44 mm H x 482 mm W x 183 mm D

(1.72” H x 19” W x 7.18” D)

Finish: Textured Black Paint

Shipping Weight: 3.9 Kg (8.5 lb)

Net Weight: 3.1 Kg (6.9 lb)

Page 12

*

SMPTE Method, 60 Hz & 7 kHz mixed 4:1 @ ± 4 dBu output

**

Input terminated with 600 ohms, unity gain, adjacent channel
driven to maximum output

Total length based on typical modular telephone cable resistance
of 12 ohms per 100 m (330 ft.)

RC-16 REMOTE CONTROL

CONTROL

Type: Incremental Rotary Bi-Phase Encoder with

Quadrature-to-Pulse Conversion Circuit

Display: Multiplexed Display Refreshed at Line

Frequency Rate by Serial Data Burst; One of
16 Concentric LEDs is Illuminated as a
Virtual Pointer

Recomm. Cable: 4-Wire Modular Telephone Cable, or 6-Wire

Modular Telephone Cable for Remote
Activation of Preset or Priority Function

Connectors: 4-Wire or 6-Wire RJ-11 Type Modular Phone

Plug

Wiring Scheme: Daisy-Chain (Loop) or Parallel Using Jacks

on Each Device Controlled

CONTACT REQUIREMENTS
Preset or Priority: Single-Pole Dry Closure or Open Collector

Transistor to Logic Ground; 128 Milliamp
Capacity

Security Key: Single-Pole Dry-Closure Switch; 25 Milliamp

Capacity

MECHANICAL

Front: 578mm (2.28”) Square

203mm (0.8”) Above Panel Surface

Rear: 533mm (2.1”) Diameter;

406mm (1.6”) Behind Front Panel

Max. Mounting

Panel Thickness: 9.6mm (0.38”)

Minimum Depth: 437mm (1.72”) Behind Front Panel

(Including Connectors)

Materials/Finish: Matte Black, Injection Molded, High-Impact

Plastic Escutcheon and Knob; Black Painted
Steel Can

Shipping Weight: 454g (1.0 lb.)

Net Weight: 114g (0.25 lb.)

ENVIRONMENTAL

Storage Temperature: -25°C to 70°C (-13°F to 158°F)

Operating Temperature: -10°C to 50°C (14°F to 122°F)

Humidity: < 80% Relative, Non-condensing

Advertising