Architectural specifications – TEKVOX TekMonitor 2 User Manual

Page 35

Advertising
background image

TEK 2

User’s Manual


V111813

35

TEK

VOX, Inc. – 210.348.6565 –

www.tekvox.com

San Antonio, TX 78216

Architectural Specifications


The device shall provide the following:

Two bi-directional RS-232 serial port

Four logic level inputs

Two logic outputs sourcing currents up to 300 ma @ 24V

Metal chassis with mounting flanges

24 volt DC operation with POE

Industry standard Ethernet supporting DHCP, ICMP (ping), TCP/IP, UDP, Telnet, SMTP

Programmable E-mail errors and usage notifications

Internal Real-Time clock

Internal timers for Lamp, Maintenance, Monthly Usage, Total Usage and Time Until System Off

Programmable Macros with conditional operators

DHCP configuration with Auto-Discovery

Interface for room occupancy sensor

Project data collection into a SQL database

TekEzLink control system protocol.


The device configuration shall be user programmable under the Windows® XP, Vista and Windows 7
operating systems. The configuration software shall provide complete setup, control and monitoring of an
apparatus.

An easy to use wizard shall provide quick setup of the device. The wizard shall provide for the ability to
load a device directly, save a configuration to a phantom device, and save a configuration to a template.

There shall be two types of configuration templates; Host and Device. The Host template shall contain
general information about a device. The Device template shall contain control information about the
monitored apparatus. Configuration templates shall be stored and recalled as required.

The configuration software shall provide for the creation of a Project from configured or phantom devices.
The contents of the Project shall be displayed in a tree like structure with the following items: Location,
Building, Group, Room and Device Name

The device shall be configured for either DHCP or Static IP addresses. The configuration software shall
provide an Auto-Discovery method which automatically locates said devices by a pass-code. Once a
device is located, the configuration software shall provide a Holding Area to display found devices by their
serial number. Devices within a Holding Area shall allow for a Drag-And-Drop method into a Project Area.

A Project shall provide a Grid View display of the devices. The Grid View shall display columns of
selected data using a format of both color and text.

The Project shall be saved and recalled as required.

Selected monitored items in the Project shall be time-stamped into a SQL database for retrieving usage,
status and asset information.

An interface for a room occupancy sensor shall be provided to automatically turn off a display device,
control lighting and provide remote status.

The device shall have certified compliance with FCC Part 15 for a Class B digital device, Canadian ICES-
003 and CE. The device shall be power using POE or POE+.

The unit shall be a TEKVOX TEK 2 TekMonitor.