General information

With multidata you have acquired one of the
most up-to-date, modern heat calculators cur-
rently available on the market.
Expressive symbols in the display and easy
menu navigation make readout simple. It can be
operated with one single button. The setting of
the data loggers (depending on the type of de-
vice) is being done via the software GMM.
The calculator is equipped with a long-life battery
made for operation during the initial verification
validity period (5 years) including a reserve of at
least another year. With a second battery you will
reach 11 years.

Initial verification

multidata is produced and tested in compliance
with the new European measuring instruments
directive (MID). According to this directive, de-
vices do no longer carry an initial verification
stamp, but rather the year of the device’s decla-
ration of conformity (recognizable on the front of
the device, for example: M09). The MID controls
the use of heat meters up to the moment they
are placed on the market resp. their first putting
into use. After this, the national regulations for
devices subject to legal verification apply within
the EU.

Technical data multidata

Temperature range

°C

1 - 150

Temperaturdifferenz

k

3 - 120

Display

Multifunctional LCD, 8-digit, floating

Display unit

MWh, kWh, GJ, MJ

Interface flow sensor

Models with contact pulsers or active pulser

(no Namur or Opto),

passive max. 1Hz / active max. 100 Hz

Temperature sensor connection

PT500, optional PT100, PT1000

Max. cable length 2-wire

12,5 m (PT500), 2,5 m (PT100), 20 m (PT1000)

Max. cable length 4-wire

20 m

Interfaces

optical, optionally ZR-Bus (RS-485), M-Bus, RS-232,

remote readout outputs

Ambient temperature

°C

5 - 55

Power supply

Battery 3.6 V Lithium,

optionally mains power supply 230V/24V

Battery lifetime

6 years, optionally 11 years

Protection class

IP 54 / IP 65, acc. to DIN 40050

Mechanical/electro-magnetic class

M1/E1

Accuracy class

according to EN1434

Measuring cycle dynamic

40s/30s/10s