Connector pin assignment – ZENNER MULTIDATA WR3 User Manual

Page 4

Advertising
background image

4

Connector pin assignment

Temperature sensors

2-wire measurement
Supply

1 - 2

Return

3 - 4

4-wire measurement (optionally)
Supply

1 - 2 / 5 - 6

Return

3 - 4 / 7 - 8

Flow sensor

Flow sensor pulse 10

GND 11


Input/Output

I/O 1

pulse

52

GND 53

I/O 2

pulse

54

GND 55

M-Bus

M-Bus L1

24

L2

25

RS-232

DTR 71

GND 72

Tx 73
Rx 74

RS-485

+UB 71

GND 72

A 73
B 74

Switch

Connection 2-wire Connection 4-wire

Depending on the meter’s mo-
del the version of the connec-
tion board can differ.

2 4

or electric devices such as motors or pumps in
the immediate vicinity of the meter (minimum
distance 1 m). Cables leaving the meter should
not be laid parallel to live cables (230V, minimum
distance 0.2 m).

Declaration of Conformity

ZENNER International GmbH & Co. KG declares
that this product with the number of the EC type-
examination certificate DE-08-MI004-PTB012
complies with the requirements of the EC direc-
tives 2004/22/EC (Measuring instruments direc-
tive) and 89/336/ EEC (electro-magnetic compa-
tibility).

The most up-to-date information about this pro-
duct and of our installation notice can be found at

www.zenner.com