Technical data flow sensor input, Passive with mechanical contact (reed), Flow sensor input – ZENNER MULTIDATA WR3 User Manual

Page 3: Typical connection

Advertising
background image

3

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

1 Hz Version: fmax = 1 Hz, Pulse-duty factor 1:1 to 1:9 Input

capacitance: approx. 10 nF, Input resistance approx 850 kOhm

100 Hz Version: not allowed

fmax = 1 Hz,

Pulse-duty factor 1:1 to 1:9

Input capacitance: approx. 15 nF,

Input resistance approx 470 kOhm

Ext. Voltage

3V … 30 V DC

Max. current

20 mA

Output frequency

1 Hz (8 Hz dynamically switching, if output

with 1 Hz is not possible)

Switching times:

1 Hz: 400ms < tp < 600 ms

8 Hz: 50ms < tp < 80 ms

1 Hz Version: fmax = 1 Hz, Pulse-duty factor 1:1 to 1:9 Input

capacitance: approx. 10 nF, Input resistance approx 850 kOhm

100 Hz Version: fmax = 30 Hz, Pulse-duty factor 1:1, Input

capacitance: approx. 2,5 nF, Input resistance approx. 850 kOhm

fmax = 1 Hz,

Pulse-duty factor 1:1 to 1:9

Input capacitance: approx. 15 nF,

Input resistance approx 470 kOhm

1 Hz Version: fmax = 1 Hz, Pulse-duty factor 1:1 to 1:9

Uhigh = 2,5 … 3,6V, Ulow = 0 … 0,3 V, Input capacitance:

approx. 10 nF, Input resistance approx 850 kOhm

100 Hz Version: fmax = 100 Hz, Pulse-duty factor 1:1

Uhigh = 2,5 … 3,6V, Ulow = 0 … 0,3 V, Input capacitance:

approx. 2,5 nF, Input resistance approx. 850 kOhm

Passive with
mechanical
contact (Reed)

Passive with
mechanical
contact (Reed)

Passive with
open drain FET

Passive with
open drain FET

Active f.ex. with
C-MOS Gate

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

Typical connection

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

pulse

52/

54

11

10

GND

pulse

11

10

pulse

11

10

VCC 2,5 … 3,6 V

U = 3 … 30 V

Imax = 20 mA

tp

tp

53/

55

52/

54

53/

55

52/

54

53/

55

GND

Uhigh = 2,5 … 3,6 V

Ulow = 0 … 0,3 V

Flow sensor input

Electrical connection

Schematic diagram

Connection data

Electrical connection

Schematic diagram

Connection data

Technical data additional inputs

Connection data outputs

Technical data flow sensor input

The duration of initial verification validity in Germany
remains 5 years for heat meters. After this period has
expired, the measuring device may no longer be used
for billing in commercial use. The regulations resp.
validity period may vary in other countries of the EU.

Electro-magnetic interference

multidata fulfils the national and international
requirements for interference resistance. To
avoid malfunctions due to other interferences,
do not install fluorescent lamps, switch cabinets

Advertising