Radio modules – ZENNER EDC – Electronic Data Capture Modul User Manual

Page 11

Advertising
background image

11

Number of digit rollers

Pulse value

Counter with 8 digit with modulator disc

1 rotation = 1 litre

6-digit counter with modulator disc (DN50-DN125)

1 rotation = 10 litres

6-digit counter with modulator disc (DN150-DN200)

1 rotation = 100 litres

6-digit counter with modulator disc (> DN300)

1 rotation = 1.000 litres

Pulse value of the modulator disc depending on the meter value

Data telegram contents (wM-Bus, M-Bus)

The EDC module can be delivered with various
data telegrams:

Data protocols

Type

A

Type

B

Type

C

Current value

Current data

Due date

Monthly value

Further 11 monthly

values

Status information 1

Status information 2

5. Radio modules

The EDC wireless M-Bus radio modules are
available in T-(standard), optionally in S- or C-
mode. Various data telegrams are available. The
modules operate unidirectional and usually send
every 20 seconds. Special versions possible.

Setting parameters:

Current status of the roller counter (register)

The water meter number related to the EDC
module

Pulse value of the modulator disc

Resetting of the status bits (tampering, error)

Resetting of all logger values (in case of re-
placement of the water meter and further use
of the EDC module)

Activation performs automatically, as soon as the
function "pulse enabled" is activated and the EDC
module scans 30 pulses from the register. The
current status of the roller counter is programma-
ble by means of the optical head using the front-
mounted optical interface of the EDC module.
The ZENNER PC-software GlobalMeterManager
(GMM) is required for programming. The configu-
ration is made by means of the GMM licence, the
universal interface MinoConnectRadio with Blue-
tooth interface and the specific ZENNER infrared
optohead IrCombiHead.

Technical specifications EDC-radio:

Transmission

mode

wireless M-Bus unidirectional,

T1 (standard), optionally

S1, C

Encryption code

AES-128 nach OMS

(device specific, optionally

customer specific)

Telegram

contents

rent value, due date, current

month value, history of the

monthly values, status

information

Transmission

interval

typically 20 s;

other configurations possible

Transmission

power

25 mW

Advertising