Combined m-bus/pulse module, Aes-key, Readout data logger – ZENNER EDC – Electronic Data Capture Modul User Manual

Page 13: Smart metering functions

Advertising
background image

13

General specifications EDC M-Bus and pulse:

Number of conductors

5

Cable length

1,5 m

Electromagn.

Compatibility

fulfils the European

Directive 89/336/EWG

Function Pulse output

Type P1 balanced

pulses

The combined M-Bus and pulse module has
been developed specifically to enable the simul-
taneous readout by two different users. In this
case the pulse version will be delivered by stan-
dard as type P1.

8. Combined M-Bus/Pulse

module

Important note

For EDC applications with simultaneous use of pulse
output and M-Bus interface, only battery powered or gal-
vanically isolated pulse modules can be connected to
the pulse outputs. Otherwise, the EDC module may be
damaged in the case of a potential difference between the
connected devices.

9. AES-Key

The EDC-modules send their data contents only
encrypted (AES-128, device-specific according to
OMS, optionally customer-specific). To enable re-
ception of the data contents and their further pro-
cessing, the AES-Key has to be furnished to the
respective recipients of the AES-Key. ZENNER
provides the AES keys to the devices usuallyby
means of electronic delivery or by customer-spe-
cific file.

10. Readout Data logger

The EDC modules have an internal memory
(data logger). The readout of the data which are
not already transmitted in the above data tele-
grams is carried out by means of the optical head
and GMM software.

Data logger:

Annual due date values:

max. 16

Monthly values

18, plus 18

semi-monthly values

Daily values

96

Quarter hour values

96

EDC Data logger

11. Smart Metering functions

Self-monitoring:

The module has an integrated battery status monitoring.

Tampering detection:

It will be detected as soon as the scanning coils
of the EDC module are affected by a magnet. In
the event memory date and time of the event will
be memorized.

Dismounting of module and meter
detection:

The detection is possible at all meters with grey
register cap. A hall sensor detects here as soon
as the EDC module was dismounted from the
register. The event memory stores the date and
time of the event.