1. Description

AMR/AMI communication module for
water meters

The EDC module (Electronic Data Capture)
for non reactive electronic pulse detection of
all ZENNER water meters whose registers are
equipped with modulator disc is ideally suited for
secure remote reading and integration of water
meters in Smart- Metering AMR/AMI Systems.

Typical applications:

Wireless remote readout of water meters with
walk-by or drive-by system

Radio transmission of the readings to mobile
or stationary receivers

Remote reading of the meters via M-Bus
systems

Remote reading via GSM module

Accurate dosing of fluids in the industrial and
commercial segment

Information of the flow volume and consump-
tion e.g. by the means of a pulse couting
module or measuremet transducer

The EDC communication module ensures that in
case of remote transmission of the readings, the
current status always will be transmitted. There
is no replica of the meter index due to pulse
counting. The pulse detection of the register’s
modulator disc occurs electronically and with-
out retroaction on the register. The electronics
detects reverse pulses which will be computed
internally, so that by means of the EDC module
always the current status of the roller counter will
be transmitted and read remotely.

,

The EDC-module is available in four different
versions:

RADIO: wireless M-Bus radio module accord-
ing to OMS-Standard (868 MHz), EN 13757-4

M-Bus: wired M-Bus-module, EN 13757-3

Pulse module: pulse module with forward and
reverse detection

M-Bus/Pulse combined M-Bus and pulse
module

The EDC modules are each powered from a bat-
tery, which –depending of the version- has a life-
time of up to 15 years.

Scope of delivery

EDC communication module with installation no-
tice, fixing screw (s), yellow adhesive securing
mark (s) and water meter lid.

Technical data

Power supply

Long life battery up to 15

years (depending on the

version)

Battery status monitoring

Yes

Operating temperature

-15 ... +55°C

Protection class

IP 68

Data logger:
Annual due date values:

max. 16

Monthly values

18, plus 18

semi-monthly values

Daily values

96

Quarter hour values

96

2. Technical data