M-bus module, Pulse modules, Deutsch italiano english españa français – ZENNER EDC – Electronic Data Capture Modul User Manual

Page 12

Advertising
background image

12

6. M-Bus module

The EDC-module as M-Bus module is used for
integration of water meters in wired M-Bus net-
works. The EDC-M-Bus module which is mount-
ed on the water meter enables the reading of the
water meter via Bus.

Cable assignment (polarity protected):

Brown

M-Bus 1

White

M-Bus 2

7. Pulse modules

The pulse modules can be delivered in three dif-
ferent versions (Table 3). Type P1 will be deliv-
ered as a standard.

EDC-Pulse

Type P1:

Type P2:

Type P3:

Output 1:

balanced* pulses

Forward pulses

Forward and reverse pulses

Output 2:

Dismounting module alarm

Reverse pulses

Flow direction (open = forward)

Function of the pulse modules output

* Reverse pulses are reduced by the corresponding number of forward pulses

Cable assignment

Green

Output 1

Yellow

Output 2

Grey

Ground (GND)

General specifications EDC M-Bus:

Number of conductors

2

Cable length

1,5 m

Electromagn.

compatibility

fulfils the European

Directive 89/336 EWG

General specifications EDC pulse

Number of conductors

3

Cable length

1,5 m

Output type N-channel

open-drain

(equivalent to

open-collector)

Max. output voltage

24 VDC

Max. output current

50 mA

Pulse length

≥ 10 ms

Output resistance (open)

110 Ώ

Output capacitance

(closed)

1 nF

Electromagn.

Compatibility

fulfils the European

Directive 89/336/EWG

Standard Pulse value

DN15-40

1 L/Imp.

DN50-125

10 L/Imp.

DN150-200

100 L/Imp

beginning DN300

1000 L/Imp