Problem: 120V AC output failure

Check the BATTERY STATUS to see if the Energy Center has sufficient battery charge
available. The system may have automatically shut-down due to low battery level. Disconnect
the AC device and follow the charging steps previously described for charging the unit.

Ensure the MAIN POWER SWITCH and the AC SWITCH are in the ON position and the AC
STATUS MONITOR displays shows the AC volts and Amps in the display. When under load the
AC output will display amperes (A) used.

Check the 120V AC output protection fuses and replace if needed with the same fuse specified in
this manual (located above the 120V AC socket).

If the problem has not cleared up, call Aervoe for further assistance.

Problem: 12V dC or uSB output failure

Check that the LIGHT OFF/ON OUTPUT and TIMER program is OFF and the DC OUTPUT LOAD #1
or #2 are in the ON position. Refer to the Wind & Solar Controller section.

Check the BATTERY STATUS to see if the Energy Center has sufficient battery charge
available. The system may have automatically shut-down due to low battery level. Follow the
charging steps previously described for charging the unit.

Ensure the MAIN POWER SWITCH and the DC SWITCH are in the ON position and the WIND &
SOLAR CONTROLLER display is functioning.

If the LOAD WITHOUT OUTPUT symbol is flashing, there is a possible overload. Remove the
12V or USB device and reset power to the unit by turning the Energy Center off and on again.

If the LOAD symbol is flashing, there is a possible short-circuit. Remove the 12V or USB
device and 4eset the system by turning the Energy Center off and on again..

Check the 12V DC output protection fuses and replace if needed with the same fuse specified in
this manual (located above the 12V DC socket).

If the problem has not cleared up, call Aervoe for further assistance.

The Energy Center 1500 battery and fuse replacement are the only features serviceable by the user. All
other repairs must be performed by Aervoe Industries, Inc. or an authorized repair facility. Failure to
follow these guidelines can damage the unit, cause injury, and voids the product warranty. Call Aervoe
and ask to speak with a product specialist for additional instructions or troubleshooting information.
800-227-0196.

SERvICE AND REPAIR