Group

Name

Cmd RespDescription

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

IN_KEYING_LUMA_LOW_LEVEL

KL KL

Minimum luma level

Rd/Wr 0

255

0

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14

IN_KEYING_LUMA_HIGH_LEVEL

KM KM Maximum luma level

Rd/Wr 0

255

255

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14

IN_KEYING_DSK_ALPHA

KA KA Brightness of DSK background

Rd/Wr 0

255

64

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14