Group

Name

Cmd RespDescription

Read /
Write

Min
Value

Max
value

Default
value

Values

Index #1

Index #2

SET_FREEZE

Sf

Sf

Freeze of the input

Rd/Wr 0

1

0

1 = Freeze

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14

SET_MOTION_DETECT

Sm Sm

0 : max correction; 15 : min
correction

Rd/Wr 0

15

15

0 = Input1
1 = Input2
2 = Input3
3 = Input4
4 = Input5
5 = Input6
8 = Input9
9 = Input10
10 = Input11
11 = Input12
12 = Input13
13 = Input14