Analog Way Eikos LE - EKS400 Programmer's Guide User Manual
Page 4
Advertising
4
5) Read command with 2 indexes : SET_ASPECT_RATIO_OUT
Read command to know how is displayed a signal plugged on the input 4: 3,so
Answer: so3,2<CR><LF> which mean that the input 4 is displayed cropped
A4: Error codes
Answer: E10<CR><LF> which mean invalid command
Answer: E11<CR><LF> which mean index value error (index value out of range)
Answer: E12<CR><LF> which mean index number error (too or few indexes)
Some commands are only available as [Read command], they are status and are colored in blue as this line.
Some commands are colored in yellow as this line to indicate they were added or modified in this version.
A5 COMMUNICATION PORTS
Advertising
This manual is related to the following products: