36 dimensions & technical data, G270ve model – without mixing valve, Technical data is subject to change – AquaMAX G270VE Series User Manual
Page 37
36
Dimensions & Technical Data
G270VE Model – Without Mixing Valve
Storage capacity (L)
135
Connections
Hot water delivery (L)
140
Cold water inlet
RP¾/20
Recovery rate *
135 L/Hr @ 45°C
Hot water outlet
RP¾/20
First hour capacity (L)
270
PTR valve
RP½/15
Mass
(kg)
Empty
65
Gas inlet
(flared compression)
½/15
Full
200
Condensate drain
On request
Max Supply Pressure
Gas Details
With ECV (kPa)
960
Hourly consumption (MJ/hr)
30
Without ECV (kPa)
1120
Min supply pressure (kPa)
NG: 1.13 or
LP: 2.75
ECV setting (kPa)
1200
Max supply pressure (kPa)
NG & LP: 3.5
PTR Valve (kPa)
1400
Burner pressure (kPa)
NG: 1.0 or
LP: 2.7
* Based on an inlet water temperature of 15°C.
Technical data is subject to change.
APPROVALS:
This unit complies with AS 3498
WaterMark Licence No. WMKA00200