Step 3.

M

Mode B. After manually setting Reflective Sensor Force Mode, if it is

needed to reset the printer to its default Transmissive Sensor and exit

from Force Mode, refer to the steps below:

1. Push the Release Latch to open the printer module. Ready LED

will start flashing.

2. Press and hold Feed button for about 5 seconds, when Power

LED and Ready LED start to flash simultaneously, the setting is

complete. Release Feed button immediately.

3. In about 3 seconds, Ready LED will be flashing again. Close the

printer module and then press firmly at the both sides to properly

latch it until you hear a click.

4. I

※ Printer transfers between the two modes as described above.