System Installation

AXP 1410 Installation and Use (6806800H70L)

86

3.4

Powering Down the System

Procedure

Follow these steps to shut down your AXP 1410.

1. Shut down all software operations and the operating system. For shelves with

independently running segments, each segment must be shut down.

2. Turn each circuit breaker on the front of PEM A and PEM B to the OFF position.

3. Disable the DC power at each of the external sources (branch circuit or power

distribution unit) for both PEM A and PEM B.

4. This completely removes power from the shelf and its subassemblies.

3.5

Emergency Power Off

Procedure

Read this caution and follow the next steps if it is necessary to remove power during an
emergency situation.

Step 2 removes the input power from the slots in the AXP 1410 shelf only. It does not
remove power to the PEMs. To remove power to these components, refer to the next step.

Following this procedure will result in a loss of data and may cause damage to chassis
components in a running platform. Use this method only when normal shutdown
procedures cannot be followed.