Commands Execution

ViewCheck on ATCA-9405 Installation and Use (6806800S51D)

80

5.4.5

set-poll-interval-default

set-poll-interval-default

command is used to reset the Poll interval value to default

value of a particular monitor.

Syntax for CLI
set-poll-interval-default monitorId <Monitor ID> deviceInstance

<Dev Instance>

Syntax for XML
<Script>

<InvokeMethod>

<Object>

<Class>deviceCategory</Class>

<Name>SP_VEE0-{Dev Cat}</Name>

</Object>

<Method>setPollIntervalDefault</Method>

<Argument>

<Name>deviceInstance</Name>

<Value>Dev Instance</Value>

</Argument>

<Argument>

<Name>monitorId</Name>

<Value>Monitor ID</Value>

</Argument>

</InvokeMethod>

</Script>]]>]]>

Dev Instance

Enum

Use list-device-instances CLI command to get the
equivalent enumerated value of supported Device
Instance

PollInterval Value

Integer

Type the Poll interval value for the specified monitor ID

Table 5-18 set-poll-interval

Argument

Data Type Description