2 monitoring device critical errors, Table 5-28, Monitors – Artesyn ViewCheck on PrAMC-7311 Installation and Use (May 2014) User Manual

Page 86: Commands execution

Advertising
background image

Commands Execution

ViewCheck on PrAMC-7311 Installation and Use (6806800S45C)

86

The following table provides list of Monitor IDs and Device Instances for each of the Monitors
being monitored on PrAMC-7311.

5.5.2

Monitoring Device Critical Errors

Under Linux OS, the Device Drivers LOG abnormal behavior and potential errors occurring in
the Hardware device with KERN_ERR or KERN_CRIT category. These notifications are
considered as potential errors as they could manifest into latent faults in the live system.

As part of monitoring the Device Critical errors, all such Kernel CRITICAL and Kernel ERROR
notifications have been extracted from the PNE Kernel (3.0) driver sources and represented in
the form of a database.

The In Service Monitoring Module of ViewCheck would watch out for the occurrence of these
notifications and on detection would send a notification to XML.

The Device Errors are captured and are identified uniquely by ERROR ID. For definition of
ERROR ID, refer

Error ID

on page 19

.

Table 5-28 Monitors

Monitor Description

Monitor
ID

Valid Device Instances

Remarks

CPU Core
Temperatures

1000

core 0 and core 1

Temperature of the

2

cores

available on

PrAMC-7311

CPU

are monitored individually and
reported if crosses a Set
Threshold.

HDD Health Status

1010

sda1 to sda10

Monitors the Health Status of the
sda1 to sda

10

partitions on the

HDD and reports.

Network Errors

1020

eth0-4

Monitors the various Error
counters for each of the Network
Device Instances and provides an
error counter exceeds the rate of
change.

Network Counters

1021

eth0-4

Monitors the various counters for
each of the Network Device
Instances