Portable air compressor – Westward 3JR70A User Manual

Page 11

Advertising
background image

11- ENG

Westward Operating Instructions and Parts Manual

Model 3JR70A

Portable Air Compressor

Description of Operation (continued)

Outlet Pressure Gauge: The

outlet pressure gauge indicates the

air pressure available at the outlet

side of the regulator. This pressure

is controlled by the regulator and is

always less than or equal to the tank

pressure.

Tank Pressure Gauge: The tank

pressure gauge indicates the reserve

air pressure in the tank.

Regulator: Controls the air pressure

shown on the outlet pressure gauge.

Turn the knob clockwise to increase

pressure and counterclockwise to

decrease pressure.

Drain Valve: The drain valve is

located at the base of the air tank and

is used to drain condensation at the

end of each use.

On/

Auto/Off

Switch

Cooling System (not shown): This

compressor contains an advanced

design cooling system. At the heart of

this cooling system is an engineered

fan. It is perfectly normal for this fan

to blow air through the vent holes in

large amounts. You know that the

cooling system is working when air is

being expelled.

Air Compressor Pump (not shown):

Compresses air into the air tank.

Working air is not available until the

compressor has raised the air tank

pressure above that required at the

air outlet.

Check Valve: When the air

compressor is operating, the check

valve is "open", allowing compressed

air to enter the air tank. When the

air compressor reaches "cut-out"

pressure, the check valve "closes",

allowing air pressure to remain inside

the air tank.

Check Valve

Regulator

Safety

Valve

Outlet

Pressure

Gauge

Tank Pressure Gauge

Pressure

Switch

Drain Valve

Advertising