Portable air compressor, Service and adjustments – Westward 3JR70A User Manual

Page 14

Advertising
background image

14- ENG

Westward Operating Instructions and Parts Manual

Model 3JR70A

Portable Air Compressor

Service and Adjustments

5. Make sure the valve disc moves

freely inside the check valve

and the spring holds the disc in

the upper, closed position. The

check valve may be cleaned

with a solvent, such as paint and

varnish remover.

6. Apply sealant to the check valve

threads. Reinstall the check valve

(turn clockwise).

7. Replace the outlet tube and

tighten the nut.

8. Perform the Break-in Procedure.

See "Break-in Procedure" in the

Operation section.

Unit cycles

automatically

when power is on. When doing

maintenance, you may be exposed

to voltage sources, compressed air

or moving parts. Personal injuries

can occur. Before performing any

maintenance or repair, unplug the

compressor and bleed off all air

pressure.

ALL MAINTENANCE AND REPAIR

OPERATIONS NOT LISTED MUST

BE PERFORMED BY A TRAINED

SERVICE TECHNICIAN.

In closed position

disc is visible.

In open

position

nothing is

visible.

Screwdriver

TO REPLACE OR CLEAN CHECK

VALVE

1. Release all air pressure from air

tank. See "To Drain Tank" in the

Maintenance section.

2. Unplug unit.
3. Loosen the nut on the outlet tube

and move the outlet tube to the

side.

4. Unscrew the check valve (turn

counterclockwise) using a socket

wrench.

Outlet Tube

Check

Valve

Nut

TO REPLACE REGULATOR

1. Release all air pressure from air

tank. See "To Drain Tank" in the

Maintenance section.

2. Unplug unit.
3. Using an adjustable wrench

remove the gauges and quick

connect from the regulator.

4. Remove the regulator.
5. Apply pipe sealant tape to the

nipple on the standpipe.

6. Assemble the regulator and

orient as shown.