Portable air compressor – Westward 3JR70A User Manual

Page 17

Advertising
background image

Westward Operating Instructions and Parts Manual

Model 3JR70A

Portable Air Compressor

17- ENG

Regulator will

not shut off air

outlet.

1. Damaged regulator

1. Replace

1. It is normal for "some"

pressure drop to occur.

1. If there is an excessive

amount of pressure drop

when the accessory is

used, adjust the regulator

following the instructions

in the "Description of

Operation" paragraph in

the "Operation Section.

NOTE: Adjust the regulated

pressure under flow

conditions (while accessory is

being used).

Compressor is not

supplying enough

air to operate

accessories.

1. Prolonged excessive use

of air.

2. Compressor is not

large enough for air

requirement.

3. Hole in hose.

4. Check valve restricted.

5. Air leaks.

1. Decrease amount of air

usage.

2. Check the accessory

air requirement. If it is

higher than the SCFM

or pressure supplied

by your air compressor,

you need a larger

compressor.

3. Check and replace if

required.

4. Remove and clean, or

replace.

5. Tighten fittings.

1. Damaged regulator

1. Replace

Regulator knob

has continuous

air leak.

Pressure reading

on the regulated

pressure gauge

drops when an

accessory is

used.

Symptom (s)

Possible Causes (s)

Corrective Actions (s)