Portable air compressor, Troubleshooting chart – Westward 3JR70A User Manual

Page 16

Advertising
background image

16- ENG

Westward Operating Instructions and Parts Manual

Model 3JR70A

Portable Air Compressor

Symptom (s)

Possible Causes (s)

Corrective Actions (s)

Voltage sources, moving parts, or compressed air

sources are exposed when repairing the compressor.

Personal injury can occur. Unplug the compressor before attempting any

repairs.

Troubleshooting Chart

1. Pressure switch does

not shut off motor when

compressor reaches

"cut-out" pressure.

2. Pressure switch "cut-

out" too high.

1. Move On/Auto/Off lever

to the "OFF" position. If

the outfit does not shut

off contact a trained

service technician.

2. Contact a trained service

technician.

Excessive tank

pressure - safety

valve pops off.

1. Tube fittings are not

tight enough.

1. Tighten fittings where air

can be heard escaping.

Check fittings with soapy

water solution.

Do Not

Overtighten.

Air leaks at

fittings.

Air leaks in air

tank or at air

tank welds.

1. Defective air tank.

1. Air tank must be

replaced. Do not repair

the leak.

Do not

drill into,

weld or otherwise modify

air tank or it will weaken.

The tank can rupture or

explode.

Air leaks

between head

and valve plate.

1. Leaking seal.

1. Contact a trained service

technician.

1. Possible defect in

safety valve.

1. Operate safety valve

manually by pulling on

ring. If valve still leaks, it

should be replaced.

Air leak from

safety valve.

1. Possible defect in safety

valve.

1. Operate safety valve

manually by pulling on

ring. If valve still leaks, it

should be replaced.

Knocking Noise.

Advertising