Installation, Vent installation, Vent location – Avalon Firestyles DVS Insert EF-2001 to 2005 User Manual

Page 12: Vent configurations, For qualified installers only) © travis industries

Advertising
background image

1 2

Installation

(for qualified installers only)

© Travis Industries

4041213

1 0 0 - 0 1 1 5 0

Vent
Installation

Inlet

Exhaust

Inlet

Exhaust

Termination

(Simpson

Part # 991)

DV Chimney

Liner Kit

(Simpson Part

# 923GK)

3” Gas

Liner

High-Temp.

Silicone

Apply high-temperature

silicone to the liners on

both ends and secure

with 2 screws.

Make sure to route the exhaust liner to the exhaust portion of the cap.

High-Temp.

Silicone

Vent Location

2-1/2"

(64 mm)

15-3/4"

(400 mm)

2-1/2"

(64 mm)

13-1/2"

(343 mm)

Center Line

13-1/4"

(337 mm)

Inlet (3” (75 mm) Dia.)

Exhaust (3” (75 mm) Dia.)

Fireplace

Opening

Vent
Configurations

Z.C. (Metal) firebox

Inlet & Exhaust Re-Line

Exhaust Only Re-Line

(recommended)

Direct Vent Cap

(part # 991)

Recommended Block-Off
Plate (non-combustible
metal and/or insulation).
Prevents odors from
chimney entering room.

3" Gas

Liner

Dura-Vent Termination Kit

(part # 923GK)

The block-off plate must
seal the intake to the
chimney space. This
way air is drawn down
the chimney for
combustion air.

Block-Off Plate
(non-combustible
materials)

NOTE: You may use either re-line configuration with a masonry or zero-clearance fireplace.

Inlet

Exhaust

Inlet

Exhaust

Masonry Fireplace

Suggestion:
Paint the fireplace cavity
with latex paint to eliminate
the possibility of odors from
the fireplace circulating into
the room.

Any cracks or
damage inside the
chimney must be
repaired.

Advertising