Caution, Safety label, Travis industries – Avalon Firestyles DVS Insert EF-2001 to 2005 User Manual

Page 29

Advertising
background image

Safety Label

2 9

© Travis Industries

4041213

1 0 0 - 0 1 1 5 0

The safety (listing) label is
on a plate chained to the
gas control valve. A copy
of the safety label is
shown to the right.

DVS Insert

Vented Gas Fireplace Heater

Tested to:

ANSI Z21.88b-1999 “V

ented Gas Fireplace Heater” and UL

307b-1995 “Gas Burning Heating

Appliances for Manufactured Hom

es”.

This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code,

ANSI Z223.

1/NFP

A

54.

Installation in Manufactured or Mobile Homes must conform with Manufactured Home Construction and Safety Standard, T

itle 24 CFR

,

Part 3280.

This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired,

the optional

factory conversion kit must be used.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,

permanently located, manufactured (mobile) home where not prohibited by local codes. See owner

’s manual for details. This appli

ance is

not convertible for use with other gases, unless a certified kit is used.

This vented gas fireplace heater is not for use with air filters.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

This appliance must be properly connected to a venting system in accordance with the manufacturer

’s installation instructions.

Use only

approved coaxial direct vent system to vent this appliance to the exterior

. See owner

’s manual for approved brands of venting.

W

ARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to th

e owner

’s

information manual provided with this appliance. For assistance or additional information consult a qualified installer

, servic

e agency or

the gas supplier

.

VENTED GAS FIREPLACE HEA

TER – NOT FOR USE WITH SOLID FUEL

CAUTION:

Hot while in operation. Do not touch. Severe burns may result.

Keep children, clothing, furniture, gasoline and other liquids having flammable vapors away

.

Do not operate this appliance with glass removed, cracked or broken. Replacement of the

panel(s) should be done by a licensed or qualified service person.

Report No. 028-S-15b-5

Certified for USA

4800 Harbour Pointe Blvd. SW Mukilteo, W

A

98275

Minimum Clearances to Combustibles

Faceplate to Sidewall

..............

6”

Max 8” Deep Mantle Height

Above Faceplate

.........

10”

Front of Unit

.............................

36”

Side Facing to Faceplate

...........................................

6”

Top Facing to Faceplate

............................................

8”

Hearth Extension Front

.............................................

12”

Hearth Extension Sides

.............................................

0”

L.P
.

N.G.

L.P
.
N.G.

Input Rate on “HI” (BTU/Hr)*

. . . . . .

31,000

31,000

Minimum Inlet Pressure (inches W

.C.)

. . . . . . . .

11”

5.5”

Input Rate on “LO” (BTU/Hr)*

. . . . .

21,600

24,900

Maximum Inlet Pressure (inches W

.C.)

. . . . . . . .

13”

7”

Main Burner Orifice (DMS)*

. . . . . . .

.0625

#37

Manifold Pressure on “HI” (inches W

.C.)

. . . . . .

10”

3.5”

This room heater is equipped at the factory for use with natural gas. If conversion to propane (LP) fuel is desired the

optional factory conversion kit must be used.

Blower Electrical Rating:

115v
, 1.5

Amps, 60 Hz F

AN TYPE VENTED CIRCULA

T

OR

Manufacture

2004

Jan.

Apr
.

Jul.

Oct.

Date:

2005

Feb.

May

Aug.

Nov

.

2006

Mar

.

Jun.

Sep.

Dec.

(IGN) 0284

Advertising