Installation, Alcove installation requirements – Avalon Firestyles Cottage User Manual

Page 12

Advertising
background image

12

Installation

(for qualified installers only)

Travis Industries

93508113

4 020325

Alcove Installation Requirements

Whenever the stove is placed in a location where the ceiling height is less than 7' tall, it is considered
an alcove installation. Because of the reduced height, the special installation requirements listed
below must be met.

Chimney connector and chimney must be one of the following types:

• DURAVENT model DVL with DURATEC chimney
• DURAVENT model DVL with DURA-PLUS chimney
• AMERI-TEC model DCC with model HS chimney
• SECURITY model DL with SECURITY model ASHT or S2100 chimney
• METAL-FAB model DW with TG chimney

• GSW Double Wall Chimney Connector with Super Chimney Twenty-One
• SELKIRK METALBESTOS model DS connector with model SSII chimney
• I.C.C. Excel (2100-2 Can.) (103-HT USA) chimney with HP connector
• Standard Masonry Chimney with any one of the above listed connectors

Minimum Clearance
(See the illustration above)

Co m b u st i b l

e Alcove

N o n -

Combustible

A l c o v e

A

Sidewall to stove

18"

8"

B

Backwall to stove

11-1/2"

3"

D

Connector to sidewall

27-1/4"

17-1/4"

E

Connector to backwall

12-1/2"

4-1/2"

G

Maximum Depth of Alcove

48"

48"

H

Minimum Width of Alcove

61-1/8"

41-1/8"

J

Minimum Height of Alcove

84"

6" Above Stove Top

Alcoves are classified as combustible or non-combustible. Non-combustible alcoves must have
walls and a ceiling that are 3 1/2" thick of a non-combustible material (brick, stone, or concrete).
This non-combustible material must be spaced and ventilated at least 1" off of all combustible
materials (walls, ceiling, etc.) to allow air to move around the non-combustible walls and ceiling.
All other alcoves are considered combustible. The clearances below must be met:

Non-combustible alcove

construction (on walls

and ceiling) - see the

explanation above.

3 1/2" thick non-

combustible

material

Combustible materials

1" Min.

Ventilated

air space

Non-combustible

reinforcer

a

b

d

e

h

j

g