Adjusting the Burn Rate

Use the air control slider to control the burn rate of the stove. See the illustration below for details.

Low Burn

(air control closed)

High Burn

(air control open)

Use the air control to

change the burn rate.

Approximate Air Control
S e t t i n g s :

Overnight Burn .............. Fully closed to 1/64" open

Medium Burn.................. 1/64" open to 1/32" open
Medium High Burn ........ 1/32" open to 1/16" open
High Burn........................ 1/16" to fully open

The air control becomes hot during operation - use gloves or a tool to prevent burns.

The air control may take several minutes to influence the burn rate. When making adjustments, you may
wish to let the stove burn for 10 minutes to gauge performance.

Ash Removal

ASHES

Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes
should be placed on a noncombustible floor or on the ground, away from all combustible
materials, pending final disposal. Ashes should be retained in the closed container until all
cinders have thoroughly cooled.