Gas adjustment (Conversion to LPG for the hob top)

All work must be carried out by a GASSAFE

registered engineer.

IMPORTANT: Always isolate the cooker from the electricity

supply before changing the injectors and/or adjusting the

minimum flow of the burners.

o

Remove the pan supports, burner cap and burner rings.

o

Unscrew the injector and replace it with the required injector for

the new gas supply according to the table below.

Burner Type

Gas Type Pressure

Mbar

Injector

Marking

(1/100mm)

Power

(Kw)

Max Min

Auxiliary (Small)

Natural

Gas

20

72

1

0.3

Liquid Gas 28..30/37

50

Semi Rapid

(Medium)

Natural

Gas

20

97

1.75 0.6

Liquid Gas 28..30/37

65

Rapid (Wok)

Natural

Gas

20

135

3.3

1

Liquid Gas 28..30/37

90

o

When all four jets have been replaced, reassemble all the

burners carefully, taking particular care to make sure that the

burners and burner caps are aligned properly.

o

After changing the injectors YOU MUST change the minimum

flow rate.