Minimum flow adjustment for hob gas taps.

All work must be carried out by a GASSAFE

registered engineer.

o

Ignite the large (rapid) burner and set the control knob to the

minimum position.

o

Remove the control knob to access a small adjusting screw.

o

Using a suitable screwdriver, turn the screw clockwise to

decrease the flow of gas and make the flame smaller. Turn the

screw anti-clockwise to increase the flow of gas and make the

flame bigger.

o

To establish the correct adjustment, the flame should be

approximately 3 – 4 mm in length. For Butane / Propane gas,

the adjusting screw must be tightly screwed in.

o

Refit the control knob.

o

Turn the control knob to maximum and then back to minimum

two or three times to make sure the flame does not go out when

the control knob is set to minimum.

o

If the flame does go out then remove the control knob and

repeat the procedure again.

o

Repeat these steps for the semi-rapid and auxiliary burners.