Unscrew the injector and replace it with the required injector for

the new gas supply according to the table below.

Burner Type

Gas Type Pressure

Mbar

Injector

Marking

(1/100mm)

Power

(Kw)

Max Min

Oven Burner

Natural

Gas

20

1.15

2.1 0.8

Liquid Gas 28..30/37

0.72

Grill Burner

Natural

Gas

20

1.15

2.1 0.8

Liquid Gas 28..30/37

0.72

o

After changing the injectors YOU MUST change the minimum

flow rate.

Minimum flow adjustment for the oven and grill burners

All work must be carried out by a GASSAFE

registered engineer.

o

In order to access the adjusting screws to change the minimum

flow rate of the grill and oven burners, you need to remove the

hob top and control panel.