2-15

3.5

Basic parameters

The basic parameters contain the general settings of the machine. Changes
effect all programmed seams.

Attention

As a factory setting, the basic parameters are optimized. Improper changes
may cause faults in the machine process, which may lead to a reduction of
quality and damages to the machine.

Follow this procedure to changes basic parameters:

1. Press the P-key.

2. Press F4.

3. Select the desired basic parameter using the arrow keys.

4. Press ENT-key.

5. Enter the desired value.

6. Repeat steps 3. to 5. for all desired basic parameters.

7. Press the P-key to leave the submenu.

During the selection of the parameters, you can scroll line per line using the
vertical arrow keys. You can also select the pages directly:

Key 0:

basic parameters 01 - 14

Key 1:

basic parameters 10 - 23

Key 2:

basic parameters 20 - 33

Key 3:

basic parameters 30 - 40

The following basic parameters can be changed [factory-set values in square
brackets]:

01

Front positioning point [135 mm]
distance between insertion position and seam start; if seam length is
changed only the seam end is varied

02

Middle positioning point [225 mm]
with this setting the seam start is calculated that if the seam length is
changed, seam start and end are delayed the same; is used for back
pocket with dart, if dart shall be positioned in the middle of the pocket

03

Rear positioning point [315 mm]
distance between insertion position and seam end; if seam length is
changed, only the seam start is varied
Length of main clamp

165 mm

set value

205 mm

245 mm

285 mm

290 mm

330 mm

Attention

This parameter defines the end of the main clamp. If this parameter is set too
large, there may be sewing problems while sewing flaps.

04

Folder up after [335 mm]
time of the folder lifting after the seam; if distance too short, folder gets
caught by the fold pushers

05

Thread length full spool [57 m]
a wrong thread length leads to incorrect values in the display of
remaining thread

06

Time for picking up [0,6 sec.]
delay of the piping taking; independant how fast the operator is able to
insert the piping; if you enter ‘9.9 sec.’, the piping will be picked when