Thermoglaze 25 TS

LACK OF HUMIDITY OR UNEVEN HUMIDITY

Possible Causes

What To Do

Low water.

Refill water reservoir/Check water is on.

Defective humidity control.

Replace the humidity control.

Defective water heat element.

Replace the water heat element.

Restriction or sediment in the water line or
the water heat box inlet hole.

Clean out water line.

Loose wire or bad connection in humidity
circuit.

Repair loose wire or connection in
humidity circuit.

Blower is not running.

See “Blower Will Not Run” section

Doors out of alignment.

Align doors.

BLOWER WILL NOT RUN

Possible Causes

What To Do

Control box power switch is not “on.”

Flip switch to “on” position.

Defective blower motor.

Replace blower motor.

Defective control box power switch.

Replace control box power switch.

Loose wire or bad connection in blower
control circuit.

Repair loose wire or bad connection.