Belshaw Adamatic TG25 Thermoglaze User Manual

Page 41

Advertising
background image

Belshaw Bros., Inc.

• www.belshaw.com • Phone 206-322-5474 • Fax 206-322-5425

Thermoglaze 25 TS

MN-1728EN

17

TG Parameter Settings


Tables 1, 2 and 3 below list of the temperature controller default settings and the Belshaw Factory
settings. When installing a new controller 3 of the default setting must be changed to the Belshaw
Factory settings.

• Push and hold the scroll key

for 3 seconds, this will take you to the “SEt” menu.

• Push the scroll key

once to access the “LocK” parameter.

• Push the Up

or down

arrow keys to change “LocK” to “nonE”.

• Push the scroll key

to page through the settings and the Up

or down

arrow keys to

change the settings listed in the Belshaw “Factory” column. (see tables 1, 2 and 3)

When finished setting parameters.

• Continue pushing the scroll key

until you are back to “LocK”.

• Push the Up

or down

arrow keys to set “LocK” to “uSEr”.

• Push the reset key

to return normal operation.


Default Settings:


In the event that parameters have been modified without recording the modifications, change each
parameter to match those listed in Tables 1, 2 and 3 listed below (controller parameter default settings).
Then adjust SP1H, PB, OUT2 and the LocK parameters as listed in Belshaw “Factory” below. Then set
SP1 to 420ºF.