WATER SUPPLY REQUIREMENTS

The set up procedure on the next page must be followed to

allow the steaming system to function correctly

THIS EQUIPMENT IS TO BE INSTALLED TO COMPLY WITH THE

APPLICABLE FEDERAL, STATE, OR LOCAL PLUMBING CODES



ƒ All ovens with steam require a ½” NPT hot or cold water supply at a pressure

of 2 - 3 bar (29 – 44 psi). Located approximately 10” from the right and 4” from
the top of the stand when facing the front of the oven.


ƒ Only one water supply is required per oven. A manifold supplies all decks from

one connection point.


ƒ For proper operation of the steam system it is recommended that the water

supply follows the following specifications:

Hardness

2-4 grains per gallon


PH range

7.0 to 8.0


Chloride concentration

0 –30 ppm


Consult your water treatment company for proper water filtration system
information.

ƒ No drain is required for this oven.

ƒ A non-return check-valve is supplied fitted to the water inlet manifold.




MONO FG257 HARMONY MODULAR DECK 01/07 RAC