Disposal, Technical data – Beurer WL 80 User Manual

Page 15

Advertising
background image

15

• Protect the device from impacts, humidity, dust,

chemicals, marked temperature fluctuations and nearby

sources of heat (ovens, heaters).

10. Disposal

For environmental reasons, do not dispose of the device

in the household waste at the end of its useful life.

Dispose of the device at a suitable local collection

or recycling point. Observe the local regulations

for material disposal. Dispose of the device in

accordance with EC Directive – WEEE (Waste

Electrical and Electronic Equipment). If you have any

questions, please contact the local authorities responsible

for waste disposal.

11. Technical data

Illuminance

Max. approx. 2500 lux

(at distance of 15 cm)

Light

LED technology

Light levels

20 light levels with simulation

of dawn

Mood light

Automatic RGB colour change,

option of setting individual colour

Wake-up light

function

Off, 2, 5, 10, 15, 20, 30, 45,

60 minutes prior to alarm

Sunrise function

Maximum light intensity up to

alarm: Light level 5, 10, 15, 20

Snooze duration

1, 2, 5, 10, 20, 30 minutes

Sunset function

2, 5, 10, 15, 20, 30, 45, 60 minutes

Good night

function

(sleep radio)

2, 5, 10, 15, 20, 30, 45, 60 minutes

LCD backlighting Off, 1, 2, 3

Time

Toggle 12h/24h mode, 15 minute

buffer in event of power failure

Alarm

3 alarm times (Off, On, Day)

Alarm tone, 8 sounds, radio,

MP3 via USB stick

Button tone

Off, On

AUX

Line-in, 3.5 mm jack plug

USB

Playback via USB stick, max.

32 GB.

File formats: MP3, WMA, WAV,

max. 9999 files, can only be read

in root directory, subdirectories

are not supported. 5 V output

voltage

Radio

Frequency range VHF 87.5-108

MHz, 10 memory spaces

Speaker

2 Watt

Mains part

voltage supply

Input: 110-240 V, AC, 50/60 Hz,

0.5 A

Output: 9 V, DC, 1500 mA

Mains part

protection class

Protection class II

Subject to technical changes.